TIA TIA/EIA-455-211
TA TAEA-455-211 2000-SEP-26 FOTP-211 EC 61290-2-3 Optcal Fbre Amplfers - Basc Specfcaton Part 2-3 Test Methods for Optcal Power Parameters - Optcal Power Meter
TA TAEA-455-211 2000-SEP-26 FOTP-211 EC 61290-2-3 Optcal Fbre Amplfers - Basc Specfcaton Part 2-3 Test Methods for Optcal Power Parameters - Optcal Power Meter
Scope and object
This part of IEC 61290 applies to optical fibre amplifiers (OFAs) using active fibres, containing rare-earth dopants, presently commercially available.
The object of this standard is to establish uniform requirements for accurate and reliable measurements, by means of the optical power meter test method, of the following OFA parameters, as defined in clause 3 of future IEC 61291-1:
a) nominal output signal power;
b) large-signal output stability;
c) saturation output power;
d) maximum input signal power;
e) maximum output signal power;
f) input power range;
g) output power range;
h) maximum total output power.
NOTE - All numerical values followed by (+) are currently under consideration