JEDEC JESD57 1996-DEC-01 Test Procedures for the Measurement of Sngle-Event Effects n Semconductor Devces from Heavy on rradaton
JEDEC JESD57 1996-DEC-01 Test Procedures for the Measurement of Sngle-Event Effects n Semconductor Devces from Heavy on rradaton
This test method defines requirements and procedures for ground simulation and single event effects (SEE) and implementation of the method in testing integrated circuits. This standard is valid when using a cyclotron or Van de Graaff accelerator. Microcircuits under test must be delidded. The ions used at the facilities have an atomic number Z gt; 2. It does not apply to SEE testing that uses protons, neutrons, or other lighter particles. This standard is designed to eliminate any misunderstanding between users of the method and test facilities, to minimize delays, and to promote standardization of testing and test data.