This Technical Specification gives guidance for the assessment
of confomity to be included in the manufacture's quality plan as
part of his quality system.
This Technical Specification includes:
a) requirements for materials, components, joints and assemblies
given in the applicable Part (s) of EN ISO 15875;
b) requirements for the manufacturer's quality system;
NOTE 1 It is recommended that the quality system conforms to EN
ISO 9001:2000[2].
c) definitions and procedures to be applied if third party
certification is involved.
NOTE 2 If third party certification is involved, it is
recommended that the certification body is accredited to EN
45011[3] or EN 45012[4], as applicable.
In conjunction with the other parts of EN ISO 15875(see
Foreword), this Technical Specification is applicable to
crosslinked polyethylene (PE-X) piping systems intended to be used
for hot and cold water installations within buildings for the
conveyance of water, whether or not intended for human consumption
(domestic systems) and for heating systems, under design pressures
and temperature appropriate to the class of application (see Table
1 of EN ISO 15875:2003).