Cart

No products

Shipping $0.00
Total $0.00

Cart Check out

DS DS/EN ISO 9614-3

DS DSEN SO 9614-3 2009-SEP-09 Acoustcs - Determnaton of sound power levels of nose sources usng sound ntensty - Part 3 Precson method for measurement by scannng

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$57.00 tax incl.

$114.00 tax incl.

(price reduced by 50 %)

1000 items in stock

1.1 This part of ISO 9614 specifies a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined. Surface integration of the intensity component normal to the measurement surface is approximated by subdividing the measurement surface into contiguous partial surfaces, and scanning the intensity probe over each partial surface along a continuous path which covers the extent of the partial surface. The measurement instrument determines the averaged normal intensity component and averaged squared sound pressure over the duration of each scan. The scanning operation can be performed either manually or by means of a mechanical system. The octave band or band-limited weighted sound power level is calculated from the measured one-third-octaveband values. The method is applicable to any source for which a physically stationary measurement surface can be defined, and on which the sound generated by the source under test and by other significant extraneous sources are stationary in time. The source is defined by the choice of measurement surface. The method is applicable in specific test environments fulfilling all relevant requirements of this part of ISO 9614. This part of ISO 9614 specifies certain ancillary procedures, described in annex C, to be followed in conjunction with the sound power determination. The results are used to indicate the quality of the determination, and hence the grade of accuracy. If the quality of the determination does not meet the requirements of this part of ISO 9614, the test procedure shall be modified in the manner indicated. This part of ISO 9614 is not applicable to any frequency band in which the sound power of the source is found to be negative on measurement. 1.2 This part of ISO 9614 is applicable to sources situated in any environment which is neither so variable over time as to reduce the accuracy of the measurement of sound intensity to an unacceptable degree, nor subjects the intensity measurement probe to gas flows of unacceptable speed or unsteadiness (see 5.2.2, 5.3 and 5.4). In some cases it will be found that the test conditions are too adverse to allow the requirements of this part of ISO 9614 to be met. For example, extraneous noise levels can exceed the dynamic capability of the measuring instrument or can vary to an excessive degree during the test. In such cases the method given in this part of ISO 9614 is not suitable for the determination of the sound power level of the source.

Customers who purchased DS DS/EN ISO 9614-3
also purchased
  • DS DS/EN ISO 3746 : Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
  • AAMI 7198 : Cardiovascular implants—Tubular vascular prostheses
  • AAMI HE75 : Human Factors Engineering – Design of Medial Devices
  • AASHTO GVCB AMD : Guide Specifications and Commentary for Vessel Collision Design of Highway Bridges-Second Edition; 2010 Interim Revision
See More Documents

Contact us