DS DS/EN 50441-3

DS DSEN 50441-3 2006-JUL-19 Cables for ndoor resdental telecommuncaton nstallatons - Part 3 Screened cables - Grade 3

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$26.50 tax incl.

$53.00 tax incl.

(price reduced by 50 %)

1000 items in stock

These cables are for installation in indoor Residential Cabling Systems. They are specified
up to 1 000 MHz. Their design is based on the requirements of the EN 50290-2-1. They are
specifically designed for cabling in residential environment supporting ICT and BCT
applications. (Telephone, Computer and TV services). This specification defines the
constructional details as well as the specific performances of the cables.
Unless otherwise specified, all cables covered by this standard may be subjected to
voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of
the low voltage directive. Due to current limitation related to the conductor cross sectional
area, they are not intended for direct connection to mains electricity supply. The maximum
current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in
the relevant detail specification.