DS DS/EN 50121-3-2

DS DSEN 50121-3-2 2006-SEP-12 Ralway applcatons - Electromagnetc compatblty - Part 3-2 Rollng stock - Apparatus

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$33.00 tax incl.

$66.00 tax incl.

(price reduced by 50 %)

1000 items in stock

This Standard applies to emission and immunity aspects of EMC for electrical and electronic
apparatus intended for use on railway rolling stock. EN 50121-3-2 applies for the integration of
apparatus on rolling stock.
The frequency range considered is from d.c. to 400 GHz. No measurements need to be performed at
frequencies where no requirement is specified.
The application of tests shall depend on the particular apparatus, its configuration, its ports, its
technology and its operating conditions.
This standard takes into account the internal environment of the railway rolling stock and the external
environment of the railway, and interference to the apparatus from equipment such as hand-held radio
transmitters.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators,
e.g. transponder systems), then the emission and immunity limits in this standard at the
communication frequency do not apply.
This standard does not apply to transient emissions when starting or stopping the apparatus.
The objective of this standard is to define limits and test methods for electromagnetic emissions and
immunity test requirements in relation to conducted and radiated disturbances.
These limits and tests represent essential electromagnetic compatibility requirements.
Emission requirements have been selected so as to ensure that disturbances generated by the
apparatus operated normally on railway rolling stock do not exceed a level which could prevent other
apparatus from operating as intended.
Likewise, the immunity requirements have been selected so as to ensure an adequate level of
immunity for rolling stock apparatus.
The levels do not however cover extreme cases which may occur with an extremely low probability of
occurrence in any location. Specific requirements which deviate from this standard shall be specified.
Test requirements are specified for each port considered.
These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.

Customers who purchased DS DS/EN 50121-3-2
also purchased
  • DS DS/EN 50155 : Railway applications - Electronic equipment used on rolling stock
  • DS DS/EN 50121-4 : Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
  • BSI BS EN 61000-6-2 : Electromagnetic Compatibility (EMC) - Part 4-29: Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations on D.C. Input Power Port Immunity Tests
  • DS DSF/EN 61000-6-3/FprA1 : Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
See More Documents

Contact us