TIA TIA-455-187
TA TA-455-187 1991-JUL-01 FOTP-187 Engagement and Separaton Force Measurement of Fber Optc Connector Sets-ANS APPROVAL WTHDRAWN MARCH 2004
TA TA-455-187 1991-JUL-01 FOTP-187 Engagement and Separaton Force Measurement of Fber Optc Connector Sets-ANS APPROVAL WTHDRAWN MARCH 2004
INTRODUCTION
Intent
The purpose of this procedure is to measure the forces or torques that are required to fully couple or uncouple a connector set.
Description
The connector set components are held in a fixture so that a controlled coupling force or torque can be applied. The force or torque is measured during the entire coupling and/or uncoupling cycle. The procedure is applicable to either twist type or push-pull type coupling mechanisms.
Alternative Procedures
This test procedure is an alternative to the measurement procedure, titled Engagement and Separation Force of IEC 874-1, Third Edition.
Customers who purchased TIA TIA-455-187