SAE USCAR-35
SAE USCAR-35 2007-OCT-01 Test Procedures for Evaluatng Bolt-Load Retenton of Magnesum Alloys
SAE USCAR-35 2007-OCT-01 Test Procedures for Evaluatng Bolt-Load Retenton of Magnesum Alloys
A bolt-load retention (BLR) test is a practical test to determine the bolt load of a fastener joint with time and at given temperatures. There are three types of BLR tests described in this standard, namely generalpurpose test, design-purpose test, and screening material test. A general-purpose BLR test may be used for screening materials, while a design-purpose BLR test is usually used to verify the BLR behavior of a specific joint. The screening material test is an example of the general-purpose test for typical automotive applications.
The test procedures provides guidance in the following areas: (a) BLR sample and test fixture, (b) test fastener, washer and nut, (c) bolt-load measurement and data acquisition, (d) heating device, (e) initial loading, (f) baseline test, and (g) instrumentation of strain gages and calibration (see Appendix B). A designpurpose test procedure differs from a general-purpose test procedure mainly in the areas dealing with sample and fixture, test washer and nut, and initial loading.
This standard is intended to evaluate and/or validate BLR of magnesium alloys, especially cast magnesium alloys, for automotive applications. It is implied that the test samples mentioned in this standard are to be produced from casting processes but are not restricted to castings and magnesium alloys.
This standard is intended to evaluate BLR behavior during long-duration BLR tests. The effect of thermal cycling without holding the samples at high temperatures for a long period of time is discussed in Appendix C.