SAE MA1520A
SAE MA1520A 2001-OCT-01 Areas for Calculatng Stress or Load Values for Metrc MJ Externally Threaded Fasteners
SAE MA1520A 2001-OCT-01 Areas for Calculatng Stress or Load Values for Metrc MJ Externally Threaded Fasteners
Areas for the standard metric series of thread diameter-pitch combinations for aerospace externally threaded fasteners are established for the following conditions:
a. Area for ultimate shear stress or load in unthreaded shank.
b. Area for ultimate tensile stress or load in thread.
c. Area for stress durability test load in thread.
d. Area for stress-rupture test load at elevated temperature.
e. Area for tension-tension fatigue test load.
Purpose:
This standard specifies the areas to be used in calculating stress or load values for use in metric externally threaded fastener procurement specifications and for information of designers.