SAE AS245B
SAE AS245B 2000-APR-01 Water Soluton Type Hand Fre Extngusher
This specification covers the following types and classes of extinguishers:
Type I Stored pressure type
Category A - Temperature range -40 to +140
Category B - Temperature range +35 to +140
Type II Cartridge operated type
Category A - Temperature range -40 to +140
Category B - Temperature range +35 to +140
Purpose:
To specify minimum requirements for a water solution type hand fire extinguisher which shall be suitable for use on incipient fires which may occur in an airplane cabin interior. The type of fire for which these units are intended is one involving combustible materials such as paper, textiles and similar materials.