SAE ARP1109B
SAE ARP1109B 1997-SEP-01 Dynamc Testng Systems for Oxygen Breathng Equpment
This SAE Aerospace Recommended Practice (ARP) recommends performance requirements for test equipment used in dynamic testing of aviation oxygen breathing equipment. This document describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.
Classification:
This recommended practice covers but is not limited to the following types and classes of systems.
Types:
Type I Mechanical breathing simulator (either bellows or piston type) only generating sinusoidal patterns
Type II Mechanical breathing simulator (generally cam-actuated, bellows or piston type or pre-programmed, servocontrolled) generating any shape of breathing pattern
Type III Pneumatic breathing simulator pre-programmed, servocontrolled generating any shape of breathing pattern
Classes:
Class A Military aircraft oxygen systems
Class B Transport category and General Aviation oxygen systems
NOTE: This classification applies whether the breathing simulator is an individual system or if it is permanently incorporated into a complete test set-up.