SAE AMS72951C 2006-FEB-01 Radographc Flm 5-80
Form:
This specification covers one type of high-contrast, fine-grain radiographic film in the form of cut sheets or rolls.
Application:
This film will provide a radiographic quality level of 1-1T sensitivity when properly utilized (See AMS 7295).
Classification:
High contrast with gradient of 5.0 or better and exhibiting resolution of 80 or more lines per millimeter.